248 research outputs found

    Automated Feedback for 'Fill in the Gap' Programming Exercises

    Get PDF
    Timely feedback is a vital component in the learning process. It is especially important for beginner students in Information Technology since many have not yet formed an effective internal model of a computer that they can use to construct viable knowledge. Research has shown that learning efficiency is increased if immediate feedback is provided for students. Automatic analysis of student programs has the potential to provide immediate feedback for students and to assist teaching staff in the marking process. This paper describes a “fill in the gap” programming analysis framework which tests students’ solutions and gives feedback on their correctness, detects logic errors and provides hints on how to fix these errors. Currently, the framework is being used with the Environment for Learning to Programming (ELP) system at Queensland University of Technology (QUT); however, the framework can be integrated into any existing online learning environment or programming Integrated Development Environment (IDE

    Plans for the first balloon flight of the gamma-ray polarimeter experiment (GRAPE)

    Get PDF
    We have developed a design for a hard X-ray polarimeter operating in the energy range from 50 to 500 keV. This modular design, known as GRAPE (Gamma-Ray Polarimeter Experiment), has been successfully demonstrated in the lab using partially polarized gamma-ray sources and using fully polarized photon beams at Argonne National Laboratory. In June of 2007, a GRAPE engineering model, consisting of a single detector module, was flown on a high altitude balloon flight to further demonstrate the design and to collect background data. We are currently preparing a much larger balloon payload for a flight in the fall of 2011. Using a large (16-element) array of detector modules, this payload is being designed to search for polarization from known point sources of radiation, namely the Crab and Cygnus X-1. This first flight will not only provide a scientific demonstration of the GRAPE design (by measuring polarization from the Crab nebula), it will also lay the foundation for subsequent long duration balloon flights that will be designed for studying polarization from gamma-ray bursts and solar flares. Here we shall present data from calibration of the first flight module detectors, review the latest payload design and update the predicted polarization sensitivity for both the initial continental US balloon flight and the subsequent long-duration balloon flights

    GRAPE: a balloon-borne gamma-ray polarimeter

    Get PDF
    The Gamma-RAy Polarimeter Experiment (GRAPE) is a concept for an astronomical hard X-ray Compton polarimeter operating in the 50 - 500 keV energy band. The instrument has been optimized for wide-field polarization measurements of transient outbursts from energetic astrophysical objects such as gamma-ray bursts and solar flares. The GRAPE instrument is composed of identical modules, each of which consists of an array of scintillator elements read out by a multi-anode photomultiplier tube (MAPMT). Incident photons Compton scatter in plastic scintillator elements and are subsequently absorbed in inorganic scintillator elements; a net polarization signal is revealed by a characteristic asymmetry in the azimuthal scattering angles. We have constructed a prototype GRAPE module that has been calibrated at a polarized hard X-ray beam and flown on an engineering balloon test flight. A full-scale scientific balloon payload, consisting of up to 36 modules, is currently under development. The first flight, a one-day flight scheduled for 2011, will verify the expected scientific performance with a pointed observation of the Crab Nebula. We will then propose long-duration balloon flights to observe gamma-ray bursts and solar flares

    Scintillator gamma-ray detectors with silicon photomultiplier readouts for high-energy astronomy

    Get PDF
    Space-based gamma-ray detectors for high-energy astronomy face strict constraints of mass, volume, and power, and must endure harsh operating environments. Scintillator materials have a long history of successful operation under these conditions, and new materials offer greatly improved performance in terms of efficiency, time response, and energy resolution. The use of scintillators in space remains constrained, however, by the mass, volume, and fragility of the associated light readout device, typically a vacuum photomultiplier tube (PMT). Recently developed silicon photomultipliers (SiPMs) offer gains and efficiencies similar to those of PMTs, but with greatly reduced mass and volume, high ruggedness, and no high-voltage requirements. We have therefore been investigating the use of SiPM readouts for scintillator gamma-ray detectors, with an emphasis on their suitability for space- and balloonbased instruments for high-energy astronomy. We present our most recent results, including spectroscopy measurements for lanthanum bromide scintillators with SiPM readouts, and pulse-shape discrimination using organic scintillators with SiPM readouts. We also describe potential applications of SiPM readouts to specific highenergy astronomy instrument concepts

    Simulations of a monolithic lanthanum bromide gamma-ray detector

    Get PDF
    We have been working on the development of a detector design for a large area coded aperture imaging system operating in the 10-600 keV energy range. The detector design is based on an array of Lanthanum Bromide (LaBr3) scintillators, each directly coupled to a Hamamatsu 64-channel multi-anode photomultiplier tube (MAPMT). This paper focuses on the development of the GEANT4-based simulations as an aid in the optimization of the detector design. The simulations have been validated by comparisons with various laboratory data sets. We will summarize the current status and latest findings from this study

    Analysis of the distributional consequences of the introduction of the Council Tax in England in 1993.

    Get PDF
    The thesis's principal aim is to investigate the distributional impact of the introduction of the Council Tax as the Community Charge's replacement in England in April 1993. The thesis's empirical analyses consider the distribution of the local tax burden at the household level in terms of income groups, household types and geographical location. The research models the introduction of the Council Tax using a large set of data provided by the Nationwide Anglia Building Society. These data comprise details of over 75,000 mortgages granted by the Building Society between 1988 and 1990 and are sufficiently detailed to allow calculation of individual and household liability for both Community Charge and Council Tax. The Council Tax is chiefly a property tax based on the capital value of domestic property. Because the capital value of domestic property is unevenly distributed both geographically and across income groups, necessarily the Council Tax's burden is also distributed geographically and across income groups. Previous distributional analyses of the impact of the Council Tax have been unable to consider this spatial distribution. However, the Nationwide Anglia data allow analysis of this spatial distribution. The thesis considers a number of influences on the tax's distribution - the use of capital value as a tax base; the operation of the Revenue Support Grant; the Council Tax Transitional Relief Scheme; the Council Tax's hybrid personal / property tax design; as well as the distributional implications of the transition to a form of property tax from the Community Charge's flat- rate poll tax. The final chapter uses the implications of the preceding distributional analyses to consider the Council Tax in the longer term as part of a broader solution to the historic difficulties of the overall local government finance system

    A fast scintillator Compton telescope for medium-energy gamma-ray astronomy

    Get PDF
    The field of medium-energy gamma-ray astronomy urgently needs a new mission to build on the success of the COMPTEL instrument on the Compton Gamma Ray Observatory. This mission must achieve sensitivity significantly greater than that of COMPTEL in order to advance the science of relativistic particle accelerators, nuclear astrophysics, and diffuse backgrounds, and bridge the gap between current and future hard X-ray missions and the high-energy Fermi mission. Such an increase in sensitivity can only come about via a dramatic decrease in the instrumental background. We are currently developing a concept for a low-background Compton telescope that employs modern scintillator technology to achieve this increase in sensitivity. Specifically, by employing LaBr3 scintillators for the calorimeter, one can take advantage of the unique speed and resolving power of this material to improve the instrument sensitivity while simultaneously enhancing its spectroscopic and imaging performance. Also, using deuterated organic scintillator in the scattering detector will reduce internal background from neutron capture. We present calibration results from a laboratory prototype of such an instrument, including time-of-flight, energy, and angular resolution, and compare them to simulation results using a detailed Monte Carlo model. We also describe the balloon payload we have built for a test flight of the instrument in the fall of 2010

    A new low-background Compton telescope using LaBr3 scintillator

    Get PDF
    Gamma-ray astronomy in the MeV range suffers from weak fluxes from sources and high background in the nuclear energy range. The background comes primarily from neutron-induced gamma rays, with the neutrons being produced by cosmic-ray interactions in the Earth\u27s atmosphere, the spacecraft, and the instrument. Compton telescope designs often suppress this background by requiring coincidences in multiple detectors and a narrow time-of-flight (ToF) acceptance window. The COMPTEL experience on the Compton Gamma Ray Observatory shows that a 1.9-ns ToF resolution is insufficiently narrow to achieve the required low background count rate. Furthermore, neutron interactions in the detectors themselves generate an irreducible background. By employing LaBr3 scintillators for the calorimeter, one can take advantage of the unique speed and resolving power of the material to improve the instrument sensitivity and simultaneously enhance its spectroscopic performance and thus its imaging performance. We present a concept for a balloon- or space-borne Compton telescope that employs deuterated liquid in the scattering detector and LaBr3 as a calorimeter and estimate the improvement in sensitivity over past realizations of Compton telescopes. We show initial laboratory test results from a small prototype, including energy and timing resolution. Finally, we describe our plan to fly this prototype on a test balloon flight to directly validate our background predictions and guide the development of a full-scale instrument

    An imaging neutron/gamma-ray spectrometer

    Get PDF
    We present the design and development of a dual-species, neutron/γ-ray imaging spectrometer for the identification and location of radioactive and special nuclear materials (SNM). Real-time detection and identification is important for locating fissile materials. These materials, specifically uranium and plutonium, emit neutrons and γ rays via spontaneous or induced fission. Co-located neutron and γ-ray emissions are a sure sign of fissile material, requiring very few spatially correlated events for a significant detection. Our instrument design detects neutrons and γ rays from all sources in its field of view, constructs images of the emission pattern, and reports the spectra for both species. The detection principle is based upon multiple elastic neutron-proton scatters in organic scintillator for neutrons, and Compton scattering in organic scintillator followed by photoelectric absorption in inorganic scintillator for γ rays. The instrument is optimized for neutron imaging and spectroscopy in the 1-20 MeV range. We recorded images and spectra of a Cf-252 source from 0.5 - 10 MeV, and have done similarly for several γ-ray sources. We report the results of laboratory testing of this expanded instrument and compare them to detailed Monte Carlo simulations using Geant4
    corecore